I/O MODULES






Digital Input Modules
Features
- μs from input to logic | All input can be as counters | Hot Swap | Invert at hardware level
- Modules have 200 Mhz CPU, Debounce setting for each DI channel in ms
- Available module variables: heartbeat, temperature, operating hours, hours since restart, restart counter, serial number, input voltage…. and many more
Settings at module hardware level
Digital Output Modules
Features
- Hot Swap | Fail-safe with Force Low, Force High, Keep Last State
- 200 MHz CPU (Intelligent module that can make decisions without the CPU card)
- Available module variables: heartbeat, temperature, operating hours, hours since restart, restart counter, serial number, input voltage…. and many more
Relay Output Modules
Features
- 2A relay | Hot Swap | Fail-safe with Force Low, Force High, Keep Last State
- 200 MHz CPU (intelligent module that can make decision without the CPU card)
- Available module variables: heartbeat, temperature, operating hours, hours since restart, restart counter, serial number, input voltage…. and many more
Analogue Input Module
Features
- Ch-Ch isolation | Hot Swap | Ch range: -20-20mA, 0-20mA, 4-20mA, 0-10V, -10-10V…..
- 200 MHz CPU, adjustable filter & delta change, 24 bit ADC, 16bit resolution
- Available module variables: heartbeat, temperature, operating hours, hours since restart, restart counter, serial number, input voltage…. and many more
PT100/1000 Module
Features
- Ch-Ch isolation | Hot Swap | Temperature measurement : -100°C to 300°C
- 200 MHz CPU, Effective resolution: 16bits , Measurement Resolution: 0.5°C Measurement Accuracy: ± 0.5°C
- Available module variables: heartbeat, temperature, operating hours, hours since restart, restart counter, serial number, input voltage…. and many more
Settings at module hardware level
Analogue Output Modules
Features
- Ch-Ch isolation | Hot Swap | Ch range: -20-20mA, 0-20mA, 4-20mA, 0-10V, -10-10V…..
- 200 MHz CPU, adjustable filter & delta change, 16bit resolution, fail-safe
- Available module variables: heartbeat, temperature, operating hours, hours since restart, restart counter, serial number, input voltage…. and many more
Combination Modules
Features
- Hot Swap | Ch range: -20-20mA, 0-20mA, 4-20mA, 0-10V, -10-10V, 0-5V, 1-5V,……
- 200 MHz CPU, 16bit AI/AO, fail-safe on AO & DO, DI as counters, invert at hardware level
- Available module variables: heartbeat, temperature, operating hours, hours since restart, restart counter, serial number, input voltage…. and many more
Combination Modules
Features
- Same features as DI and DO modules combined
- 200 MHz CPU, fail-safe with Force Low, Force High, Keep Last State
- Available module variables: heartbeat, temperature, operating hours, hours since restart, restart counter, serial number, input voltage…. and many more
Highspeed Counter Modules 5 KHz
Features
- Hot Swap | fail-safe with Force Low, Force High, Keep Last State
- 200 MHz CPU (intelligent module that can make decisions without the CPU card)
- Available module variables: heartbeat, temperature, operating hours, hours since restart, restart counter, serial number, input voltage…. and many more
Settings at module hardware level
Redundancy Module
Features
- This solution mirrors data via the backplane and through the REDLINK connection.
- It is only necessary to program one CPU module – the program is automatically mirrored to the redundant CPU.
Power Supply
Features
- Hot Swap | fail-safe with short circuit check every 10 ms
- Variables for input voltage, output voltage, warnings, current overload alarms, load in %
- Available module variables: heartbeat, temperature, operating hours, hours since restart, restart counter, serial number, input voltage…. and many more
Adding IO modules in Brodersen Worksuite
Introduction to LB2 I/O Series
The Brodersen LB2 I/O modules are designed for the RTU32M & RTU32N series. The I/O modules are in two parts, a bottom part containing the backplane bus, and a top part containing the I/O board and logic. All LB2 modules are hot swappable and equipped with a 200 MHz processor to process I/O, handle filtering, SOE, debounce, module clock and general module logic. Diagnostic variables are available for all LB2 I/O modules. Please see the module datasheets for full info.
Module firmware update is handled at the RTU level from the Brodersen WorkSuite.
Use only genuine Brodersen bus cables for connection to Brodersen RTUs and for extension of I/O module blocks. The connection cables for the LB2 backplane bus are designed to meet the power requirements and shielding to run high speed communications. The maximum overall length of a complete system is 40 meters. Each LB2 I/O module & power supply module is calculated as 2 cm. The cables are as the length indicates, e.g. UCC-610/1 count as 100 cm.
The maximum system configuration is 60 I/O modules on one LB2 Bus. If the configuration exceeds 60 I/O modules, an additional CPU is required.